Course Code: BP105T
Unit III Overview
Quality Control of Drugs of Natural Origin (WHO Guidelines). A medicinal raw material must have the correct identity, acceptable purity and suitable constituent content. This unit explains how observations, microscopy, laboratory measurements and DNA evidence are combined to assess a batch.
Topics Covered – Syllabus Coverage
| Required topic | Coverage |
|---|---|
| Quality principles and adulteration | 3.1-3.3 |
| Organoleptic evaluation | 3.4 |
| Qualitative microscopy | 3.5 |
| Quantitative microscopy | 3.6-3.7 |
| Physical, chemical and biological evaluation | 3.8-3.10 |
| Extractive values and moisture | 3.11-3.12 |
| Foreign matter and ash values | 3.13-3.14 |
| Bitterness, foam and haemolysis | 3.15-3.17 |
| Swelling, viscosity, optical rotation and refractive index | 3.18-3.21 |
| Acid and saponification values | 3.22-3.23 |
| DNA barcoding and interpretation | 3.24-3.25 |
| Revision and examination practice | 3.26 |
Learning outcomes
- Recognise adulteration and explain how to investigate it.
- Compare organoleptic, microscopic, physical, chemical and biological evaluation.
- Calculate leaf constants and identify diagnostic tissue features.
- Explain every physicochemical parameter in the syllabus, with its principle and interpretation.
- Solve calculations using correct units, blanks and dilution factors.
- Explain DNA barcoding and its limitations in processed materials.
- Combine test results into a justified quality decision.
Essential terms
| Term | Meaning |
|---|---|
| Identity | Correct source and medicinal part |
| Purity | Acceptable freedom from unwanted material |
| Assay | Quantitative determination of a constituent or activity |
| Marker | Compound selected for analytical monitoring |
| Fingerprint | Characteristic pattern of several constituents |
| Blank | Test without the sample, used for correction |
| Monograph | Defined description, tests and acceptance limits for a material |
The guiding question
Can a batch look genuine yet contain exhausted material, excess moisture or the wrong species? Which tests would reveal each problem?
3.1 Quality control: identity, purity and strength
Quality control is the examination of a material against defined requirements to determine whether it is suitable for its intended use. For natural drugs, the starting point is the correct biological source and medicinal part.
Two materials with the same common name may belong to different species; two parts from the same plant may have different constituents.
Three central questions
- Identity: is this the required material?
- Purity: does it contain unacceptable foreign matter, contamination or deterioration?
- Strength: does it contain an acceptable amount of the specified constituents or demonstrate the required activity?
An attractive appearance cannot answer all three questions.
A combined approach
Macroscopic examination is rapid and useful for intact drugs. Microscopy examines cellular structures, including those surviving in powders. Chemical tests and chromatography examine constituents.
Physical measurements detect changes in composition or handling. Biological assays measure a defined response. DNA-based tests can support species authentication.
Each method has a different target and limitation.
Quality framework
Define the material and test method before testing. Obtain representative samples, use suitable equipment and controls, record observations and compare the results with the applicable specification.
Investigate an unexpected result rather than changing a limit to make the batch pass. Retain batch identity throughout receipt, analysis and disposition.
| Quality requirement | Evidence that may support it |
|---|---|
| Correct species and part | Morphology, microscopy, DNA where suitable |
| Freedom from unwanted material | Foreign matter, ash, targeted contaminant tests |
| Consistent composition | Extractive values, fingerprints and assays |
| Suitable condition | Moisture, appearance, microbial and storage checks |
WHO-oriented quality approach
The WHO quality framework links reliable identification with suitable sampling, reproducible test methods and control of contamination. Specifications must suit the particular herbal material.
Assess microbial quality and relevant residues as well as the identity and physicochemical tests. Keep equipment checks, laboratory records and traceability so a reported result can be reviewed.
Why natural drugs vary
Genetics, climate, season, age, plant part, harvest and processing can alter composition. Genuine variation must be distinguished from substitution or deterioration.
A specification allows a justified range; it does not imply that all natural batches are chemically identical. Testing should be appropriate to the form supplied: a whole leaf, powder and concentrated extract need different evidence.
Examination key: No single test proves complete quality. Species identification does not measure potency, and a satisfactory assay does not establish freedom from every contaminant.
3.2 Adulteration: types, examples and detection
Adulteration is the replacement, mixing or alteration of a drug with material that reduces its authenticity or quality. It may be deliberate for profit or arise through misidentification, careless handling or confusing names.
Intent and analytical finding are separate questions: a laboratory can demonstrate a mismatch without proving why it occurred.
Main forms
- Substitution: supplying another species or cheaper material as the intended drug.
- Admixture: mixing the genuine drug with inferior or unrelated matter.
- Exhausted material: supplying a drug from which useful constituents have already been removed.
- Artificial enhancement: adding colour, flavour or chemicals to imitate a genuine appearance or test response.
| Type | Teaching example and useful check |
|---|---|
| Inferior commercial variety | A different bark sold as the specified cinnamon; examine bark and fingerprint |
| Wrong medicinal part | Excess clove stalks mixed with flower buds; separate and inspect |
| Exhausted drug | Previously extracted cloves; compare volatile constituents and extractives |
| Unrelated bulk material | Starch added to a powdered drug; investigate starch morphology and composition |
| Added mineral matter | Sand mixed with roots; inspect foreign matter and acid-insoluble ash |
| Artificial colour | Dyed material resembling the required drug; compare microscopy and chromatographic profile |
Accidental causes
Common-name confusion, similar-looking species, mixed collection sites, harvesting the wrong organ, careless drying and poor segregation can produce an unacceptable lot.
Insect damage and fungal growth are often described as deterioration or contamination rather than substitution. All require investigation because the quality outcome may still be poor.
Detection strategy
Start with authenticated comparison material and a representative sample. Note unexpected colour, odour, size and texture. Inspect for foreign structures under the microscope.
Select chemical or physical tests that address the suspected adulterant. For example, high mineral residue suggests an ash investigation; low extractive value in an apparently genuine drug suggests exhaustion, poor extraction or deterioration.
Adulteration versus permitted substitution
A declared alternative accepted by the applicable standard is different from an undeclared replacement. Genuine material from the wrong species remains unacceptable when the specification requires another species.
A cheaper material is not automatically an adulterant; the issue is whether its identity and use match the declaration and standard.
Prevention
Authenticate suppliers, identify the source and part clearly, maintain traceability, segregate batches and use risk-based incoming tests.
Retained samples and records help compare an unexpected batch with previous acceptable ones. Procurement based only on price and common name leaves important identity risks unresolved.
3.3 Sampling, preparation and laboratory records
Sampling selects material for testing from a batch. A result can be analytically precise yet misleading when the sample represents only the cleanest portion of a mixed lot.
Natural raw materials are often heterogeneous: particles, moisture and foreign matter may not be uniformly distributed.
Representative collection
Check container labels and batch integrity. Sample according to a written plan, covering appropriate containers and positions.
Combine increments when a composite sample is justified, mix suitably and divide without selectively losing coarse or fine particles. Keep separate samples when investigating local contamination or container-to-container differences.
Preparing material for each test
Examine whole material before grinding because milling destroys useful morphology. Set aside portions for foreign matter and macroscopic tests.
Reduce other portions to the specified particle size and avoid excessive heat or loss of volatile constituents. Keep DNA samples free from cross-contamination.
A moisture sample should be sealed promptly to avoid exchange with laboratory air.
Essential records
- Batch and sample numbers, supplier, declared species and plant part.
- Collection date, container condition, sample locations and sampling method.
- Sample preparation, particle size and storage conditions.
- Method version, instrument identity and calibration or suitability checks.
- Raw observations, weights, volumes, calculations, units and result basis.
- Acceptance criteria, analyst, review and any deviation or investigation.
Controls and repeatability
A reference material gives an expected identity or response. A reagent blank reveals contributions from reagents and apparatus.
A positive control confirms that a test can produce the intended response; a negative control helps detect contamination or non-specific effects.
Replicate measurements evaluate consistency, but repetition cannot repair a non-representative sample.
Reporting basis
State whether a result applies to the material as received, to a dried sample or to a defined preparation.
Correcting to dry basis requires a suitable moisture value and a method that calls for the correction.
For an as-received result x and moisture M%:
Dry-basis result = x × 100/(100 − M)
Use this when that correction is appropriate. Do not apply it automatically to every test.
3.4 Organoleptic and macroscopic evaluation
Organoleptic evaluation uses sensory characteristics such as colour, odour, texture and, only when appropriate, taste.
Macroscopic evaluation examines visible morphology: size, shape, surface, arrangement and fracture.
Both are especially useful before powders or extracts obscure the original organ.
What to observe
For leaves, record shape, margin, venation, apex, base, petiole and upper/lower surface differences.
For bark, note thickness, curvature, outer markings and inner surface.
For roots and rhizomes, examine branching, scars, transverse appearance and fracture.
For flowers and fruits, record the diagnostic arrangement of their parts.
| Character | Analytical significance |
|---|---|
| Colour | Species, drying condition, ageing or added dye |
| Odour | Volatile constituents; loss may indicate poor storage or exhaustion |
| Surface | Hairs, wrinkles, lenticels, scars or fungal growth |
| Texture | Hard, brittle, fibrous, leathery or mucilaginous nature |
| Fracture | Short, fibrous or splintery tissue pattern |
| Dimensions | Consistency with a specified organ or commercial grade |
Examples
Clove is recognised as an unopened flower bud with a stalk-like basal region and an expanded head.
A leaf drug may have characteristic venation and hairs. A bark drug may show a particular inner colour and fracture.
These observations support identification, but a look-alike adulterant or exhausted sample may retain much of the original appearance.
Taste: an important boundary
Do not taste an unidentified, toxic, contaminated or otherwise unsuitable sample. Formal taste-based evaluation requires established identity, an appropriate material and controlled conditions.
A classroom description of bitterness or astringency is not an instruction to taste every crude drug.
Advantages and limitations
The method is quick, inexpensive and useful for screening and sorting.
Its limitations include observer variation, changing storage conditions, subjective descriptions and poor discrimination in powders.
Record observations in defined terms and compare with authenticated material. Follow uncertain findings with microscopy or another independent test.
3.5 Qualitative microscopic evaluation
Qualitative microscopy identifies characteristic tissues, cells and inclusions.
A section shows the spatial arrangement of tissues; powder microscopy identifies fragments after the original arrangement is lost.
The combination is valuable when an adulterant resembles the genuine material externally.
Diagram labels: Cuticle; upper epidermis; palisade cells; xylem; air space; phloem; lower epidermis; stomatal pore. Spongy mesophyll contains irregular cells and spaces.
Section microscopy
Prepare a thin section in the required plane, clear or stain as appropriate and mount in a suitable medium. Locate epidermis, supporting tissues, vascular bundles and secretory structures.
In a dorsiventral leaf, palisade tissue is usually concentrated toward the upper surface and spongy tissue contains conspicuous air spaces below. This organisation is not universal for every leaf.
Diagnostic features
Look for stomatal pattern, trichome type, lignified fibres, vessel thickening, stone cells, starch grains, calcium oxalate crystals and oil or resin structures. Note dimensions where useful.
A feature is meaningful in combination with others: calcium oxalate occurs in many plants and is not, by itself, a species identification.
Diagram labels: Hilum; lamellae; raphides; starch grains; crystal bundle; fibre; spiral vessel; lumen; wall thickening.
Powder microscopy
Place representative portions on slides, separate crowded particles and use appropriate mounts or reagents. Observe several fields rather than selecting a single attractive fragment.
Seek both expected features and unexpected structures. Document the magnification and scale; a photograph without a scale may not support size comparisons.
| Feature | What the analyst records |
|---|---|
| Starch | Grain shape, hilum position, lamellae and simple/compound nature |
| Calcium oxalate | Prisms, clusters, needles or other crystal forms |
| Trichome | Covering/glandular type, cells and wall features |
| Vessel | Spiral, annular, scalariform or pitted thickening |
| Fibre/stone cell | Shape, wall thickness, lumen and pits |
| Secretory structure | Location and organisation of glands, ducts or cavities |
Helpful reactions
Iodine can reveal starch; appropriate lignin reagents support recognition of lignified walls.
Reagent reactions must be interpreted with morphology and suitable controls. Excess staining, thick sections and air bubbles can hide details.
A strongly coloured background is not proof of a positive tissue reaction.
Limitations
Exhausted material can retain its tissues despite losing soluble constituents. Fine milling may destroy diagnostic fragments. Extracts may contain almost no recognisable anatomy.
Microscopy therefore complements chemical evaluation; it does not replace a constituent assay.
3.6 Quantitative microscopy: leaf constants
Quantitative microscopy measures reproducible anatomical characters under a defined method.
Leaf constants help compare a leaf drug with its expected range. Use suitable leaves, defined surfaces and representative fields; counts from a very small or damaged region can be misleading.
Stomatal number
The stomatal number is the number of stomata per unit area, commonly per mm² of epidermis.
Count each complete stomatal apparatus as one stoma.
If n stomata occur in an area A mm²:
Stomatal number = n/A
Upper and lower surfaces should be recorded separately when relevant.
Diagram labels: Guard cell; pore; epidermal cell; chloroplast. Guard-cell pair plus pore equals one stoma.
Stomatal index
SI = S × 100/(E + S)
- S: number of stomata.
- E: number of ordinary epidermal cells counted in the same area by the stated method.
The two guard cells are not counted as two stomata or added as ordinary epidermal cells.
Specify the treatment of boundary cells and use it consistently.
Worked example: hypothetical field
A field contains 12 stomata and 88 ordinary epidermal cells.
SI = 12 × 100/(88 + 12) = 12%
If its calibrated area is 0.20 mm²:
Stomatal number = 12/0.20 = 60 stomata/mm²
Index is a percentage; number is an area-based count.
Vein-islet number
A vein islet is a small enclosed area of mesophyll surrounded by the ultimate vein branches.
The vein-islet number is the number of such areas per unit area, usually mm².
Clear the leaf so fine veins are visible. Use the prescribed boundary-counting rule and average representative fields.
Veinlet-termination number
A veinlet termination is a free ending of an ultimate vein branch within the network.
Count endings per unit area. A closed vein islet and a free vein ending are different objects, so their numbers must not be interchanged.
Damaged veins and poorly cleared material cause undercounting.
Palisade ratio
The palisade ratio is the average number of palisade cells beneath one epidermal cell, determined by the prescribed tracing/counting method.
Trace a suitable group of epidermal cells, count the underlying palisade cells using consistent edge rules and divide by the number of epidermal cells examined.
Repeat in several fields.
Worked example: palisade ratio
In a hypothetical preparation, four epidermal cells overlie 24 palisade cells.
Ratio = 24/4 = 6
Average multiple observations rather than reporting a single group as the final constant. It is a ratio, not a count per mm².
Sources of error
Poor clearing, focusing on the wrong plane, counting guard cells incorrectly, overlapping fields and inconsistent boundaries alter results.
Leaf development and species characteristics also matter. Compare a defined method and material with the appropriate range; do not assume a universal leaf constant for all drugs.
3.7 Microscopic measurement and powder quantitation
Calibrating an eyepiece scale
An eyepiece micrometer has arbitrary divisions until calibrated against a stage micrometer.
Align the scales and find coinciding marks. If e eyepiece divisions equal s stage divisions, and one stage division is d micrometres:
One eyepiece division = s × d/e micrometres
Hypothetical example: 40 eyepiece divisions match 100 micrometres on the stage scale.
- Each eyepiece division = 100/40 = 2.5 micrometres.
- A fibre 18 divisions long is 18 × 2.5 = 45 micrometres.
Recalibrate when the objective or relevant optical setup changes.
Lycopodium spore method: principle
A weighed quantity of powder is mixed uniformly with a weighed spore standard of known spores per gram.
Counts of diagnostic particles relative to spores estimate the abundance of the diagnostic particles in the sample.
The spores serve as an internal counting standard rather than a chemical reagent.
General calculation
Particles per g of drug = N × L × P/(S × W)
- N: diagnostic particles counted.
- S: spores counted.
- L: mass of added spore standard in g.
- P: certified spores per g of that standard.
- W: drug powder mass in g.
Use the assigned standard value rather than assuming every spore preparation is identical.
Worked example: hypothetical mixture
Let:
- N = 200.
- S = 100.
- L = 0.050 g.
- P = 94,000 spores/g.
- W = 0.100 g.
Particles/g = (200 × 0.050 × 94,000)/(100 × 0.100) = 94,000 particles/g
The assigned P value here is part of the example data. It is not a measured result for the unknown drug.
Applications and precautions
The method can quantify a suitable diagnostic particle, such as a characteristic starch grain, where the method is established.
Mix thoroughly, disperse without selective settling and count sufficient fields. Clumps, variable particle fragmentation and unequal dispersion of spores and drug particles cause bias.
Interpreting the result
Particle abundance is not automatically percentage purity. Converting counts into drug proportion requires suitable information from authentic material and a validated relationship.
A low count may indicate dilution, but grinding damage or poor mixing can also explain it. Confirm the cause with independent evidence.
3.8 Physical evaluation: measurements and controls
Physical evaluation measures properties such as density, viscosity, optical rotation, refractive index, moisture-related loss and behaviour in water.
These properties can detect variation, contamination or processing changes, particularly in oils, gums and extracts.
Some tests are grouped as physicochemical because chemical composition controls their physical response.
Measurement conditions matter
Temperature changes viscosity, density, refractive index and liquid volume. Particle size affects extraction and swelling. Concentration affects optical rotation and polymer-solution viscosity.
Report the method and conditions with the result. A number without units, temperature or concentration may be impossible to compare.
| Property | Main use or interpretation |
|---|---|
| Relative density | Comparison of liquid composition under fixed conditions |
| Viscosity | Flow behaviour of oils or defined gum/mucilage solutions |
| Optical rotation | Net rotation by optically active constituents |
| Refractive index | Optical property useful in liquid identity and purity checks |
| Swelling behaviour | Hydration capacity of gums and mucilaginous drugs |
| Moisture-related loss | Condition, drying and storage suitability |
Relative density: supporting concept
Relative density is the ratio of the density of a sample to that of a specified reference, usually water, at stated temperatures.
It has no unit. Density itself is mass per volume and has units such as g/mL.
Do not confuse these two results when comparing liquid drugs.
Analytical discipline
Use clean apparatus, equilibrate samples and standards to the required temperature, remove bubbles where appropriate and check instrument suitability.
Run replicates when required. If a physical constant is outside its range, investigate composition, calibration and conditions before assigning a cause.
3.9 Chemical evaluation and chromatographic fingerprints
Chemical evaluation examines the constituents of a drug through identification reactions, separation and quantitative assays.
A test may detect a chemical class, a marker or a pattern of compounds. Its selectivity determines what can be concluded.
Preliminary chemical tests
Alkaloid reagents may produce characteristic precipitates; ferric chloride can react with phenolic constituents; suitable reactions can reveal classes of glycosides, steroids or terpenoids.
These are screening tests. Reagent specificity, extraction conditions and interference matter, so a positive class reaction does not uniquely identify a plant.
| Screening test | Typical target or response |
|---|---|
| Mayer or Dragendorff reagent | Alkaloid-associated precipitation; confirm specificity |
| Ferric chloride | Coloured reactions with suitable phenolic groups |
| Borntrager-type reaction | Appropriate anthraquinone derivatives after required preparation |
| Iodine | Characteristic colour with suitable starch |
Marker versus active constituent
An active constituent contributes to a defined biological effect.
An analytical marker is selected for identification or quantitation and may or may not be responsible for the effect.
A suitable marker should be detectable, sufficiently stable and useful for the material being controlled. Its presence does not prove the entire mixture is authentic.
Diagram labels: Solvent front; origin; reference lane R; test lane T; band distance 30 mm; solvent-front distance 60 mm.
TLC and HPTLC principle
A sample is applied near the base of a stationary-phase plate. A mobile phase rises by capillary action.
Different constituents move different distances according to their interactions with the two phases.
Compare the test and authenticated reference under the same conditions, including development and visualisation.
Rf = distance moved by the centre of a band/distance moved by the solvent front
Both distances are measured from the origin.
Rf is dimensionless and normally lies between 0 and 1. It changes with the method, so an isolated Rf value is not a universal identity label.
Worked example: hypothetical plate
A band moves 30 mm while the solvent front moves 60 mm from the origin.
Rf = 30/60 = 0.50
Matching this band in two lanes supports similarity under the chosen conditions. The full pattern, colour, detection response and reference identity provide stronger evidence than one matching band.
Quantitative assay
An assay measures an amount using a defined analytical method.
Chromatographic or spectrophotometric assays need calibration, appropriate standards, extraction recovery and a suitable working range.
Titrimetric assays depend on stoichiometry and a valid endpoint. Include dilution factors and state the reporting basis.
Fingerprint limitations
An added marker can imitate one test. Closely related species may share several compounds. Processing may change a profile.
A fingerprint is therefore interpreted alongside morphology, microscopy, assay and other quality tests.
Unexpected bands require investigation; they are not automatically assigned as a particular adulterant.
3.10 Biological evaluation: response and relative potency
Biological evaluation measures a defined effect in a biological system.
It can be useful when activity reflects several constituents or a chemical measurement does not adequately represent the relevant response.
Systems may involve enzymes, cells, microorganisms or other validated preparations.
Basic bioassay design
Prepare a reference and test at several concentrations. Maintain the same conditions, exposure time and endpoint.
Include controls for the system and solvent. Compare valid responses using a suitable model.
The test is interpretable only if the system responds consistently and the reference behaves as expected.
Graded and quantal responses
A graded response varies continuously, such as percentage enzyme inhibition.
A quantal response records whether a defined outcome occurs in each experimental unit.
Dose-response relationships help locate an effective concentration or compare potency. The design determines which calculation is valid.
Relative potency
For comparable preparations giving the same defined effect:
Relative potency = reference dose/test dose
State the units and preparation basis.
Hypothetical example: 2 mg of reference and 4 mg of test give the same effect.
Test potency relative to reference = 2/4 = 0.5, or 50%
This applies under those assay conditions.
Dose-response interpretation
An EC50 is the concentration producing 50% of the defined maximal effect in the chosen system; it is not automatically a therapeutic dose.
An IC50 refers to 50% inhibition in a specified assay.
Comparing these values across different systems, exposure times or endpoints can mislead.
Advantages and limitations
Bioassays address a functional response but can show biological variability and interference.
Solvent toxicity may imitate a drug effect. A response may be unrelated to the intended clinical use.
Validation, controls and appropriate experimental oversight are needed.
Haemolysis is one biological test discussed in this unit; it is not a universal safety or efficacy measure.
3.11 Extractive values
An extractive value is the percentage of material extracted by a specified solvent under specified conditions.
Water-soluble and alcohol-soluble extractive values are common examples.
The result represents a mixture of soluble substances, not necessarily a single active constituent.
Principle and procedure
Weigh a representative prepared sample. Extract with the specified solvent using a controlled maceration or hot-extraction method.
Keep the solvent composition, time and particle size consistent.
Obtain a clear extract, measure a defined aliquot, evaporate it in a tared dish, dry as directed, cool suitably and weigh the residue.
Calculation
Extractive value (%) = r × (V/v) × 100/m
- r: dried residue from the aliquot in g.
- V: total defined extract volume in mL.
- v: aliquot volume in mL.
- m: sample mass in g.
If the whole extract is dried, V/v is 1.
Apply any further dilution factor separately and state the result basis.
Diagram labels: Solvent and drug; filter paper; extract; clear filtrate; measured aliquot; dry residue. Use tare and aliquot factor in the result.
Worked example: hypothetical
A 4.00 g sample gives 100 mL of extract. A 25.0 mL aliquot leaves 0.160 g of residue.
Extractive value = 0.160 × (100/25.0) × 100/4.00 = 16.0%
Omitting the aliquot factor would incorrectly give 4.0%.
Interpretation
A low value may indicate exhausted material, poor-quality material, an unsuitable batch or inadequate extraction.
A high value may reflect genuine variation or added soluble material.
Compare with the specified solvent and method; an aqueous result cannot be substituted for an alcoholic result.
Common errors
Evaporation of solvent before volume adjustment changes concentration. Suspended particles inflate residue.
Incomplete drying increases the measured mass; overheating may decompose the residue.
A wrong aliquot, dirty dish or unrecorded dilution causes calculation error.
Use solvent blanks where the method requires them.
Remember: Extractive value is a broad compositional check. A satisfactory result does not prove that the required active constituent is present in the correct amount.
3.12 Moisture content and loss on drying
Excess moisture can favour microbial growth, enzymatic change, clumping and deterioration.
Very dry material may become fragile or lose volatile substances if overheated.
The suitable limit and measurement method depend on the material.
Loss on drying (LOD)
LOD measures the mass lost when a sample is dried under specified conditions. It may include water and other volatile components.
Weigh the sample in a tared vessel, dry at the prescribed temperature or vacuum, cool in a desiccator and reweigh.
Repeat as required until the method’s endpoint is reached.
Diagram labels: Tared sample dish; oven; desiccant; cooling chamber. Weigh, dry, cool and reweigh; cool before final weighing.
LOD (%) = (m before − m after) × 100/m before
Use sample masses after subtracting the vessel tare.
Constant mass means the prescribed successive-weighing criterion has been met; it does not mean that every chemical change is absent.
Worked example: hypothetical
- Dish tare = 30.000 g.
- Dish plus sample before drying = 35.000 g.
- Dish plus sample after drying = 34.600 g.
- Initial sample = 5.000 g.
- Loss = 0.400 g.
LOD = 0.400 × 100/5.000 = 8.0%
Dividing by the mass including the dish gives a false result.
Water-specific methods
Karl Fischer determination uses a chemical reaction to determine water under suitable conditions.
It can be useful when a water-specific measurement is required, but matrix reactions and method suitability must be considered.
Azeotropic distillation carries water with a suitable solvent and separates it for measurement; it requires appropriate recovery and apparatus.
| Method | Key distinction |
|---|---|
| LOD | Mass loss under defined drying; not always water alone |
| Karl Fischer | Chemical determination of water in a suitable matrix |
| Distillation | Collected water measured after separation |
Selecting and interpreting the method
Volatile-oil-containing drugs may lose constituents during oven drying, so equating LOD with moisture can overestimate water.
Hygroscopic samples gain water while exposed to air.
Record the time, temperature and method. Do not assume that every drug should be dried at one universal temperature.
Moisture versus water activity
Moisture content measures an amount of water.
Water activity relates to its thermodynamic availability and can help assess microbial growth potential.
Materials with the same moisture percentage can have different water activity because their components bind water differently.
These are complementary measurements rather than interchangeable terms.
3.13 Foreign organic matter and other foreign matter
Foreign organic matter includes unwanted biological material, such as other plant species, wrong plant parts, insect fragments or extraneous organic debris.
Foreign matter is a broader category and may also include inorganic material such as stones or sand, depending on the specification.
Examination
Weigh a representative portion before selective removal.
Spread it in a thin layer, inspect by eye and use magnification where necessary.
Separate the defined unwanted components, identify their categories and weigh them.
Record findings before grinding; powders may require microscopic or other methods instead of simple manual sorting.
Calculation
Foreign matter (%) = mass of defined foreign material × 100/original sample mass
Keep the original denominator. Do not divide by the mass remaining after removal.
Worked example: hypothetical
A 100.0 g sample contains:
- 1.5 g of unwanted plant fragments.
- 0.5 g of stones.
Organic foreign matter = 1.5%
Total separated foreign matter = 2.0%, if both categories are included by the method.
Reporting both as 1.5% would overlook inorganic material.
Interpretation and limitations
Presence of a dangerous contaminant may matter even when the total percentage is small.
The allowable amount and definition are material-specific.
A low foreign-matter result does not exclude dissolved contamination, pesticide residues or microbial contamination.
Sand adhering to a rough surface may be hard to separate completely; an ash test provides additional evidence.
Practical quality decision
Determine whether the finding is permitted extraneous material, wrong medicinal part, evidence of infestation or a different species.
Consider identity and safety as well as mass percentage.
Garbling can remove visible unwanted fragments, but it cannot establish that the remaining drug has acceptable constituent content.
3.14 Ash values: total, acid-insoluble and water-soluble
Ash is the inorganic residue left after controlled incineration.
It contains minerals naturally present in the material and extraneous inorganic matter.
Ash values are important checks for mineral contamination and consistency, but the composition of the residue determines its significance.
Total ash
Weigh the prepared sample in a previously ignited, tared crucible.
Heat gradually to avoid loss by spattering, then incinerate at the prescribed conditions until an appropriate carbon-free residue is obtained.
Cool in a desiccator and weigh.
Follow the method when carbon persists rather than arbitrarily increasing heat.
Total ash (%) = total ash mass × 100/sample mass
A high result can arise from excess soil or sand, naturally mineral-rich tissue, or added inorganic material. It is not proof of a single cause.
Diagram labels: Heating element; insulation; crucible; inorganic residue. Cool in a desiccator, then weigh.
Acid-insoluble ash
Treat the total ash with the specified dilute hydrochloric acid, separate the insoluble residue with suitable ash-free filtration, wash, ignite and weigh.
This fraction is especially useful for detecting siliceous matter such as sand.
Acid-insoluble ash (%) = acid-insoluble residue mass × 100/original sample mass
Water-soluble ash
Treat total ash with water, collect and ignite the insoluble residue as prescribed.
Water-soluble ash is the difference between total ash and the water-insoluble residue.
Water-soluble ash (%) = (total ash mass − water-insoluble residue mass) × 100/original sample mass
Worked example: hypothetical
A 5.00 g sample yields:
- 0.300 g total ash.
- 0.080 g acid-insoluble residue.
- 0.120 g water-insoluble residue.
Total ash = 6.0%
Acid-insoluble ash = 1.6%
Water-soluble ash = (0.300 − 0.120) × 100/5.00 = 3.6%
Important distinctions
The denominator for all three results is the original sample mass on the defined basis, not the total ash mass.
Acid-insoluble and water-insoluble residues come from different treatments and are not interchangeable.
A high acid-insoluble fraction is more suggestive of siliceous contamination than total ash alone.
Sources of error
Incomplete incineration leaves carbon and increases residue. Spattering loses material.
Ordinary filter paper introduces additional ash.
An uncooled crucible gives unreliable weighing and may damage the balance.
Contamination from tongs, dust or reagents also affects small residue masses.
3.15 Bitterness value
Bitterness value expresses the bitter response of a suitable plant material relative to a defined bitter reference under a controlled sensory method.
It is relevant to bitter drugs, but it is not a direct measurement of a single compound or a general potency assay.
Principle
Determine threshold responses for reference and test solutions under comparable conditions.
The threshold is the lowest concentration meeting the method’s defined persistent bitter response.
Observer sensitivity, temperature and recent exposure to strongly flavoured substances can affect the endpoint.
Calculation convention
For a quinine-hydrochloride comparison expressed with the standard 2000 factor:
BV = 2000 × c/(a × b), in units/g
- a: concentration of plant-material stock solution in mg/mL.
- b: mL of stock present in the threshold test portion.
- c: mg of quinine hydrochloride in the threshold reference portion.
The factor belongs to that defined convention.
Worked example: hypothetical
If:
- a = 0.20 mg/mL.
- b = 2.0 mL.
- c = 0.050 mg.
BV = 2000 × 0.050/(0.20 × 2.0) = 250 units/g
Use mass represented by the test stock, not the mass of an unrelated extract unless the method defines that basis.
Interpretation and precautions
Higher value represents stronger bitterness per unit mass in that comparison.
Different bitter constituents and sensory interference can influence the result.
Identity and suitability must be established before any formal taste-based test.
Use a controlled, qualified procedure; unknown or toxic materials are not tasted for classroom identification.
Limitations
Taste fatigue and observer variation reduce precision. Sweet, aromatic or irritating components may interfere.
An analytical assay may be preferable for some constituents, but it measures a different target.
Report the procedure and reference used rather than presenting bitterness as an intrinsic instrument constant.
3.16 Foaming index
The foaming index measures persistent foam produced by an aqueous preparation under defined shaking and standing conditions.
It is useful for saponin-containing materials because their surface activity can stabilise foam.
Foam production alone is not specific for saponins.
Diagram labels: Liquid surface; foam layer; below 1 cm; 1 cm; above 1 cm. Equal final liquid volume in each tube.
Test principle
Prepare the specified aqueous extract.
Make a series containing increasing measured volumes of this preparation, bringing each to the same final liquid volume.
Use comparable stoppered tubes.
Shake consistently, allow a defined standing period and measure foam height above the liquid surface.
Tube dimensions and shaking intensity influence the result.
Typical series conditions
A commonly taught procedure uses an aqueous decoction, successive 1-10 mL portions diluted to 10 mL, consistent shaking and a 15-minute standing period.
Read a persistent 1 cm foam layer.
- All tubes below 1 cm give FI <100.
- All above give FI >1000 and require further dilution.
The prescribed method controls the exact preparation and endpoint.
Calculation
For the conventional series with a 1 cm foam endpoint:
FI = 1000/a
Here a is the mL of the original preparation represented in the endpoint tube.
Track any preliminary dilution so a refers to the correct original preparation. It is not the final total liquid volume.
Worked example: hypothetical
A tube containing 4.0 mL of preparation, diluted to the prescribed final volume, gives the qualifying 1 cm foam layer.
FI = 1000/4.0 = 250
If the preparation was diluted first, account for that dilution before calculating the index.
Results outside the series
If all tubes remain below the endpoint, report the lower-range result specified by the method.
If all exceed it, prepare a suitable dilution and repeat.
Do not invent an exact endpoint outside the observed range.
Intermediate dilutions may improve resolution when the qualifying tube lies near the end of the series.
Errors and interpretation
Dirty glassware, residual detergent, unequal tube diameter, inconsistent shaking and early readings alter foam.
More foam does not automatically mean greater therapeutic efficacy.
Compare results made by the same method and combine them with chemical identity evidence.
3.17 Haemolytic potential
Haemolysis is rupture or loss of integrity of erythrocyte membranes, releasing haemoglobin into the surrounding liquid.
Some saponins cause this effect.
A comparative haemolytic test assesses activity under controlled conditions; it does not establish clinical toxicity or a safe human dose.
Comparative principle
Expose a suitable erythrocyte suspension to serial concentrations of test and reference preparations.
Include an intact-cell control and a complete-lysis control.
Keep cell source, suspension concentration, medium, temperature and exposure time consistent.
Determine the amount producing the defined complete-haemolysis endpoint.
Diagram labels: Cell membrane; released haemoglobin; intact control; complete lysis; cell deposit; no intact-cell pellet.
Calculation convention
When the reference is assigned 1000 units/g:
H = 1000 × a/b units/g
- a: grams of reference needed for complete haemolysis.
- b: grams of test material represented at the same endpoint.
If another reference potency is assigned, replace 1000 with that assigned value.
Worked example: hypothetical
Reference amount a = 0.0020 g and test-material amount b = 0.0100 g.
H = 1000 × 0.0020/0.0100 = 200 units/g
The less material needed for the effect, the higher its activity per gram, assuming the comparison is valid.
Reading the system
An unlysed suspension remains turbid and can yield a red-cell deposit.
Complete lysis releases haemoglobin, producing a coloured supernatant without an intact-cell deposit under the defined endpoint conditions.
Background colour from an extract may mimic haemoglobin; appropriate sample blanks and instrumental methods can help distinguish this.
Limitations
Cell age, species, osmotic conditions and mechanical damage affect sensitivity.
Unequal extraction or dilution errors alter the represented drug mass.
Haemolytic and foaming activity need not rank samples identically because their mechanisms and test conditions differ.
Handle biological material under appropriate laboratory procedures.
3.18 Swelling index
Swelling index is the volume occupied by a stated mass of a material after hydration under specified conditions, expressed per gram.
It is especially useful for mucilage-containing drugs such as isabgol and for some gums.
Hydrophilic polymers take up water and expand or form a hydrated layer.
Diagram labels: Dry material; hydrated boundary; same weighed mass; cylinder graduations. Hydration expands mucilaginous material.
Procedure principle
Weigh the specified whole, cut or powdered material into a graduated stoppered cylinder.
Add the specified liquid and mix at the prescribed intervals.
Allow hydration and settling for the required period.
Read the volume occupied by the material, including the attached mucilage, at eye level.
Use replicate determinations as required.
Typical hydration conditions
A common procedure uses a stoppered graduated cylinder with the defined sample and swelling liquid, intermittent mixing during the first hour and a further settling period.
Read replicate portions at the specified endpoint.
Material-specific instructions control the sample fineness, liquid and timing.
Calculation
Swelling index = hydrated occupied volume in mL/sample mass in g
The unit is mL/g.
The result usually represents the final occupied volume under the method; it is not automatically final volume minus initial dry volume.
Follow the stated definition if a different swelling measure is requested.
Worked example: hypothetical
Three 1.00 g portions occupy 9.6, 10.0 and 10.4 mL after the defined procedure.
Mean index = (9.6 + 10.0 + 10.4)/3 = 10.0 mL/g
If a 0.50 g portion occupies 5.0 mL:
Index = 5.0/0.50 = 10.0 mL/g
Factors affecting the result
Particle size, solvent composition, ionic strength, temperature, mixing and hydration time influence swelling.
Trapped air exaggerates volume; incomplete wetting causes uneven hydration.
A highly dispersed gel may give a poorly defined boundary, so the method and reading criteria must be appropriate.
Significance
A reduced value may indicate low mucilage content, deterioration, substitution or inappropriate test conditions.
A high value alone does not identify the material.
Compare the authentic material and method, and pair the result with identity tests and other quality parameters.
3.19 Viscosity
Viscosity describes resistance to flow.
It is useful for liquid drugs and defined solutions of gums or mucilage.
Dynamic viscosity is commonly expressed in Pa·s or mPa·s.
Kinematic viscosity is dynamic viscosity divided by density and is commonly expressed in mm²/s.
Capillary method
A suitable liquid flows between calibrated marks through a capillary under controlled conditions.
Measure transit time at a fixed temperature.
For the same instrument with appropriate corrections and Newtonian liquids:
eta test/eta reference = (rho test × t test)/(rho reference × t reference)
Here rho is density and t is flow time.
Diagram labels: Reservoir arm; upper mark; timing bulb; lower mark; capillary. Maintain temperature throughout timing.
Worked example: hypothetical
At the same temperature:
- Reference viscosity = 1.00 mPa·s.
- Test density = 1.05 g/mL.
- Reference density = 1.00 g/mL.
- Test time = 120 s.
- Reference time = 60 s.
Test viscosity = 1.00 × (1.05 × 120)/(1.00 × 60) = 2.10 mPa·s
Rotational methods
A rotating element experiences resistance from the liquid.
The instrument relates torque and speed to viscosity or flow behaviour.
Many polymer solutions are non-Newtonian, so measured apparent viscosity depends on shear conditions.
Specify spindle/geometry, speed or shear rate, concentration, temperature and preparation history.
Temperature and concentration
Many liquids become less viscous as temperature rises.
Gum-solution viscosity often changes strongly with concentration and polymer degradation.
Comparing an unreported concentration at one temperature with another is invalid.
Bubbles, particles and incomplete hydration can distort results.
Interpretation
A lower viscosity may suggest dilution or polymer degradation, while a higher value may reflect greater concentration or aggregation.
These are possible explanations, not unique diagnoses.
Confirm with preparation records, concentration checks and identity tests.
3.20 Optical rotation
An optically active substance can rotate the plane of plane-polarised light.
A polarimeter measures the net observed angle through a defined sample path.
Natural oils, sugars and extracts may contain several optically active components, so the measured rotation reflects the combined sample.
Diagram labels: Light source; polariser; sample tube; known path length; analyser; observed angle alpha.
Observed and specific rotation
Observed rotation alpha is expressed in degrees.
Specific rotation [alpha] = alpha/(l × c)
This applies when:
- l: path length in decimetres.
- c: concentration in g/mL.
If c is expressed in g per 100 mL, use:
[alpha] = 100 × alpha/(l × c)
State temperature, wavelength, solvent and concentration convention.
Worked example: hypothetical
A solution containing 10.0 g in 100 mL gives alpha = +2.0° through a 1.0 dm tube.
Specific rotation = 100 × 2.0/(1.0 × 10.0) = +20.0
This uses the stated concentration convention.
Equivalently, c = 0.100 g/mL gives:
2.0/(1.0 × 0.100) = +20.0
Measurement procedure
Use a clean tube of known length, fill without bubbles, equilibrate to the required temperature and zero/check the instrument with the appropriate blank or standard.
Record the sign and wavelength.
The sodium D line is commonly used at approximately 589 nm, but the actual method controls the setting.
Interpreting signs
Positive and negative rotation describe the direction in the polarimetric convention.
They do not establish D/L configuration or R/S stereochemistry.
A racemic mixture can show zero net rotation despite containing chiral molecules.
A mixture of different rotating substances may also cancel partially.
Quality significance
A change in rotation may indicate altered composition, adulteration or decomposition.
Concentration, solvent and temperature can also explain it.
Rotation is an identity/purity aid under defined conditions, not proof of a single molecular structure in a complex extract.
3.21 Refractive index
Refractive index (n) describes the change in light propagation in a medium.
For an absolute index:
n = c0/v
- c0: light speed in vacuum.
- v: speed of light in the medium.
It is dimensionless.
Liquid oils and extracts can have characteristic ranges when measured under specified conditions.
Diagram labels: Normal; interface; air with refractive index n1; liquid with n2 greater than n1; incidence angle i; refraction angle r. n1 sin i = n2 sin r.
Refraction principle
At an interface, light changes direction according to:
n1 sin i = n2 sin r
The incidence angle i and refraction angle r are measured from the normal, not from the surface.
When light enters a higher-index medium, it generally bends toward the normal.
Refractometer measurement
Clean the prism, apply enough sample without bubbles, equilibrate to the required temperature and read with the instrument’s defined wavelength or equivalent setting.
Check calibration with a suitable standard.
State the temperature and wavelength, commonly in notation such as nD at a specified temperature.
Worked example: hypothetical
Light enters a liquid from air approximated as n1 = 1.000.
If i = 45.0° and r = 28.0°:
n2 = sin45.0°/sin28.0° = approximately 1.506
This is a teaching calculation; routine quality testing uses a calibrated refractometer.
Significance and limitations
Changes may reflect composition, mixing, temperature or contamination.
Closely related liquids can have similar indices.
The instrument may provide a concentration scale for a particular calibrated system; that scale is not universally valid for all herbal extracts.
A refractive index alone cannot identify a complex material conclusively.
3.22 Acid value
Acid value (AV) is the number of milligrams of potassium hydroxide required to neutralise the free acids in 1 g of a sample under the specified method.
It is commonly used for fixed oils and related materials.
Free fatty acids can increase during hydrolytic deterioration.
Principle and method
Dissolve a weighed sample in the specified suitable solvent system and titrate its free acidity with standard alkali using the prescribed endpoint.
Run a blank when required.
Protect solutions from conditions that change alkali strength.
The solvent system must dissolve the sample adequately without contributing uncorrected acidity.
Calculation
AV = 56.1 × N × (V − Vb)/m
The unit is mg KOH/g.
- N: titrant normality in equivalents/L.
- V: sample titration volume in mL.
- Vb: blank volume in mL.
- m: sample mass in g.
The 56.1 factor expresses the equivalent mass of KOH with the chosen units.
Diagram labels: Clamp; graduated burette; stopcock; sample solution. Read volume and apply the correct blank.
Worked example: hypothetical
A 2.00 g oil needs 1.80 mL of 0.100 N alkali; blank requires 0.20 mL.
AV = 56.1 × 0.100 × (1.80 − 0.20)/2.00 = 4.49 mg KOH/g
Use the corrected volume rather than the full sample volume.
Interpretation
A higher value can indicate more free acids, often associated with hydrolysis or poor handling.
It is not a direct measure of peroxide formation or every aspect of rancidity.
Natural composition and the applicable specification must be considered.
Acid value and sample pH are different quantities.
Common errors
Incorrect standardisation, an obscured endpoint, sample insolubility and neglecting the blank cause bias.
Using mL as litres without changing the formula creates a thousand-fold error.
Do not replace normality with molarity unless the reaction’s equivalence relationship has been considered.
3.23 Saponification value
Saponification value (SV) is the milligrams of KOH required to saponify the ester groups and neutralise free acids in 1 g of material under a defined method.
It helps characterise fixed oils and fats.
Unlike acid value, it includes alkali consumed by esters.
Method principle
Treat a weighed sample with a measured excess of standard alcoholic KOH under a prescribed reflux procedure.
After the specified treatment, determine the remaining alkali by back-titration with standard acid.
Perform a blank through the same procedure without the sample.
A water-cooled condenser returns solvent vapour; the system is not a sealed pressure vessel.
Calculation
SV = 56.1 × N × (B − S)/m
The unit is mg KOH/g.
- N: normality of back-titrating acid.
- B: acid volume in mL for the blank.
- S: acid volume in mL for the sample.
- m: sample mass in g.
The sample consumes alkali, so less acid is normally needed for its residual alkali than for the blank.
Worked example: hypothetical
- Blank = 25.0 mL.
- Sample = 12.0 mL.
- Acid = 0.500 N.
- Oil mass = 2.00 g.
SV = 56.1 × 0.500 × (25.0 − 12.0)/2.00 = 182.3 mg KOH/g
Reversing B and S would produce an incorrect negative result.
Interpretation
For otherwise comparable triglyceride mixtures, a higher value generally corresponds to lower average molecular mass and shorter average fatty-acid chains.
Free acids, non-saponifiable constituents and other esters complicate that relationship.
It is not valid to infer one exact fatty acid from SV alone.
| Acid value | Saponification value |
|---|---|
| Free acids measured | Free acids plus saponifiable esters measured |
| Direct neutralisation titration | Excess alkali followed by back-titration |
| Sample minus blank volume | Blank minus sample back-titration volume |
| Often reflects hydrolytic deterioration | Helps characterise the oil/fat mixture |
Ester value and precautions
For results on the same suitable basis:
Ester value = SV − AV
It represents alkali consumption assigned to ester saponification in that comparison.
Incomplete reaction, solvent loss, inadequate blank matching and carbon dioxide absorption by alkali affect the measurement.
3.24 DNA barcoding: species authentication
DNA barcoding compares a standardised DNA region from an unknown material with authenticated reference sequences to support identification.
It is particularly useful when external morphology is unavailable.
It identifies biological origin; it does not measure chemical strength or prove that the correct medicinal part was used.
Diagram labels: Specimen; DNA extract; amplified region; base-call peaks; sequence; compare authenticated references. Interpret match, controls and limitations.
Basic sequence
- Sampling: choose material and prevent cross-contamination.
- Extraction: isolate DNA of suitable quality.
- Amplification: use appropriate primers and controls to amplify the selected region.
- Sequencing: obtain and check the sequence.
- Comparison: match it against curated, correctly identified references.
- Interpretation: report what the data can resolve and any uncertainty.
Common plant regions
The chloroplast regions rbcL and matK are widely used in plant barcoding.
Nuclear ITS/ITS2 and other regions can add discrimination for particular groups.
No single region resolves every species equally well.
Choice depends on the taxonomic group, reference coverage and condition of the sample.
Controls and reference quality
A negative extraction control helps reveal contamination introduced during preparation.
A no-template PCR control checks contamination in amplification reagents.
A known positive material supports amplification suitability.
Reference sequences should be linked to authenticated specimens where possible; a database label alone may be wrong.
Advantages
DNA can distinguish morphologically similar materials and support authentication of some dried or powdered drugs.
Sequence information is less directly altered by growing conditions than many chemical concentrations.
The method can help detect a substitution that is difficult to recognise in a fine powder.
Important limitations
Heating, extraction and extensive processing can degrade DNA or leave little amplifiable material.
Closely related species may share a barcode.
Mixed samples can give overlapping signals, while metabarcoding introduces amplification and interpretation biases.
Failure to amplify is not proof that the declared species is absent.
What DNA cannot establish
Leaves and roots from the same plant generally share the barcode, so the test may not establish the medicinal part.
DNA identity does not quantify active constituents, detect every mineral contaminant or exclude added chemicals.
Sequence-read proportions are not automatically the mass percentages of species in a mixture.
Reporting
Describe the material tested, region, controls, sequence quality and match limitations.
A confident identification requires sufficient discrimination and trustworthy references.
If evidence cannot resolve the species, report that limitation instead of claiming certainty from the best available match.
3.25 Combining results into a quality decision
Integrated examination
Confirm the declared species, part, batch and specification.
Review sampling and condition.
Establish identity, assess purity, quantify constituents or activity and compare all results with the acceptance criteria.
Case comparisons: hypothetical batches
Genuine anatomy, low extractives: weak clove odour and low soluble constituents may indicate exhaustion or poor storage. Check extraction performance; microscopy cannot dismiss chemical failure.
High ash: high acid-insoluble ash plus grit supports investigation of siliceous contamination. High total ash alone has other explanations.
Barcode match, poor assay: correct species can still have low strength, wrong plant part or deterioration. DNA cannot override an assay requirement.
Foam and haemolysis disagree: these measure different responses. Investigate composition, controls and conditions rather than forcing agreement.
Contaminants and disposition
Assess relevant microbial contamination, pesticides, elemental contaminants and mycotoxins with targeted tests.
Acceptable appearance or ash cannot exclude them.
Hold suspect batches for documented investigation.
Retain original data; do not average away a failure with unrelated passing results.
Keep approved, rejected and quarantined material identified.
Complete answer pattern: Definition → principle → sample/apparatus → procedure → calculation and units → significance → limitations and errors.
3.26 Rapid revision and examination practice
Recall checklist
- Quality requires identity, purity and suitable strength.
- Organoleptic tests assess sensory features; microscopy identifies tissues and measures leaf constants.
- Extractives measure soluble residue; LOD may include non-water volatiles.
- Foreign organic matter and total foreign matter differ; ash fractions answer distinct questions.
- Bitterness, foam, haemolysis and swelling need defined endpoints.
- Viscosity, rotation and refractive index need stated conditions.
- AV measures free acids; SV includes esters. DNA supports origin, not strength or plant part.
Common errors
Avoid double-counting stomata, missing aliquot factors, including vessel tare, using ash as the denominator, reversing SV volumes or comparing constants at different conditions.
Short questions
- Define adulteration and give four forms.
- Distinguish stomatal number and stomatal index.
- Why does LOD not always equal water content?
- Define acid-insoluble ash and its significance.
- Explain marker, fingerprint and active constituent.
- State two limitations of DNA barcoding.
Long-answer practice
- Explain evaluation of natural drugs with examples of organoleptic, microscopic, physical, chemical and biological methods.
- Describe qualitative and quantitative microscopy with labelled figures and calculations.
- Explain extractive, moisture and ash determinations, including errors and interpretation.
- Compare bitterness value, foaming index, haemolytic potential and swelling index.
- Describe acid and saponification values with principles, blanks and calculations.
- Explain DNA barcoding and integrate it into a batch-quality investigation.
Numerical self-check: hypothetical data
A. SI: S = 20 and E = 180.
Answer: 20 × 100/200 = 10%.
B. Extractives: 5.0 g sample, 100 mL extract, 20 mL aliquot, 0.12 g residue.
Answer: 0.12 × 5 × 100/5.0 = 12%.
C. Ash: 0.15 g residue from 3.0 g drug.
Answer: 0.15 × 100/3.0 = 5%.
D. Swelling: 0.50 g occupies 6.0 mL.
Answer: 12 mL/g.
E. AV: m = 2.0 g, N = 0.10, V − Vb = 2.0 mL.
Answer: 5.61 mg KOH/g.
F. SV: m = 2.0 g, N = 0.50, B − S = 14.0 mL.
Answer: 196.35 mg KOH/g.
Final check before an answer
Have you stated the method’s target, used the correct sample basis, defined symbols and units, and explained what the result can and cannot establish?